MIL-DTL-62220C
CAUTION: For shipment to, storage in, or prior to placing the vehicle in operation in
areas where the ambient temperature is below -20°F, lubricating oil must be drained from the
crankcases and crankcases filled with the appropriate seasonal grade of oil as specified on the
applicable specification, drawing, or technical manual. For shipments made to these areas, a red
warning tag containing the following information shall be located in a conspicuous location within
the driver's compartment: "DRAIN AND FILL WITH APPLICABLE OPERATING OIL."
3.4.1.3.5 Backrests and seats. The cushions of backrests and seats shall be covered with
paper conforming to style 2 of A-A-203 with a minimum basis weight of 40 pounds. The paper
shall be secured with tape conforming to type I of A-A-883.
3.4.1.3.6 Battery supports and retainers. Battery supports and retainers shall be
preserved with compound conforming to MIL-C-450.
3.4.1.3.7 Access covers and gaskets. After removing the access covers and gaskets from
the underside of the vehicle, unpainted metal surfaces exposed by removal of these items shall be
coated with preservative conforming to grade 4 of MIL-C-16173.
3.4.1.3.8 Winch assemblies. All unpainted and unplated surfaces of winch assemblies,
including cable drums, stay line boom, controls, and linkage, shall be coated with preservative
conforming to grade 4 of MIL-C-16173. The winch cables shall be coated with preservative
conforming to grade 1 of MIL-C-16173 and rewound on the drum after drying.
3.4.1.3.8.1 Winch gearcases. The winch gearcases shall be filled to operating level with
lubricant conforming to the specified grade of MIL-L-2105 (see 6.2).
3.4.1.3.9 Wire Ropes. The stayline cables and wire ropes shall be coated with
preservative conforming to grade 1 of MIL-C-16173.
3.4.1.3.10 Power take-off clutch. The power take-off shall be processed in accordance
with the specified level of protection (see 3.4.2 for special requirements).
3.4.1.3.11 Fire extinguishers. Fire extinguishers shall have a minimum of 90 percent of
the rated full charge. All seals shall be intact. All exterior emergency handles shall be covered
with tape conforming to MIL-T-22085, type IV. DA Form 253 or appropriate documentation
shall be completed and securely attached to each extinguisher (see 6.2.1).
3.4.1.3.12 Hydraulic system. The hydraulic system shall contain hydraulic oil conforming
to MIL-H-46170, filled to operational level as listed in TM 9-2350-292-10 Appendix F and
TM 9-2350-292-20 PMCS Table 2-1.
11