MIL-DTL-39032E
3.1.2.1.2 Drying. Resistors and accessories shall be dry or be dried in accordance with
MIL-STD-2073-1, paragraph 5.2.1.
3.1.2.1.3 Preservatives. Contact preservatives shall not be used.
3.1.2.1.4 Unit packs.
3.1.2.1.4.1 Hermetically sealed resistors except established reliability types. Hermetically sealed
resistors (including ballast tubes) shall be individually unit packed or as specified in the contract or order
in accordance with MIL-STD-2073-1 (method 10). When the net weight of resistors exceeds 5 pounds
(2.268 kilograms), the unit container shall conform to ASTM-D5118 class weather resistant, style optional,
special requirements.
3.1.2.1.4.2 Nonhermetically sealed resistors and all established reliability types. These resistors shall
be individually unit packed in accordance with the procedures specified in table I. Unless otherwise
specified in the contract, resistors conforming to MIL-PRF-39017 shall be unit packed 5 each (see 6.2).
3.1.2.1.5 Accessories (when separately acquired). Accessories, such as mounting brackets, shall be
unit packed one each in accordance with MIL-STD-2073-1 (method 10). Unit pack quantities for other
than one each shall be as specified (see 6.2).
3.1.2.1.6 Supplementary containers. Resistors and accessories unit packed in a bag or envelope
exceeding 15 cubic inches (245.85 cubic centimeters) shall be placed within a supplementary container
conforming to PPP-B-566 or PPP-B-676.
3.1.2.1.7 Intermediate packs. When the unit pack is a bag of any type or the unit pack is less than 64
cubic inches (1,049 cubic centimeters), uniform quantities of resistors or accessories of the same NSN
shall be placed in intermediate containers conforming to PPP-B-566, PPP-B-676, or ASTM-D5118.
Intermediate containers shall contain multiples of five unit packs not to exceed 100 unit packs. No
intermediate packs are required when the total quantity shipped to a single destination will result in only
one intermediate pack per shipping container.
3.1.2.2 Commercial packaging. Commercial packaging preservation shall conform to ASTM-D3951.
3.1.3 Packing. Packing shall be military level A, military level B or minimal packing (see 6.2).
3.1.3.1 Military level A. Resistors and accessories, preserved as specified in 3.1.2 shall be packed in
wood containers conforming to PPP-B-601, overseas type or PPP-B-621, class 2. Closure and strapping
shall be in accordance with the applicable container specification except that metal strapping shall
conform to ASTM-D3953-97. The requirements for military level B packing shall be used when the total
quantity of a stock numbered resistor or accessory for a single destination does not exceed a packed
volume of 1 cubic foot (0.02832 cubic meter).