PPP-C-2020A
TABLE VIII. S ampling
Lot size |
Inspection levels and sample sizes |
||||||||||
I |
II |
III |
IV |
V |
VI |
VII |
VIII |
IX |
X |
XI |
|
2 to 8 9 to 15 16 to 25 26 to 50 51 to 90 91 to 150 151 to 280 281 to 500 501 to 1200 1201 to 3200 3201 to 10000 10001 to 35000 35001 to 150000 150001 to 500000 500001 and over |
* * * * * * * * * 1250 1250 1250 1250 1250 1250 |
* * * * * * * 315 315 315 315 315 490 715 715 |
* * * * * 125 125 125 125 125 192 294 294 345 435 |
* * * * 50 50 50 50 75 116 116 135 170 200 244 |
* * * 32 32 32 32 48 73 73 86 108 123 156 189 |
* * 20 20 20 20 20 47 47 53 68 77 96 119 143 |
* 13 13 13 13 13 20 29 34 42 50 60 74 90 102 |
* 8 8 8 8 12 19 21 27 35 38 46 56 64 64 |
5 5 5 5 7 11 13 16 19 23 29 35 40 40 40 |
3 3 3 5 6 7 10 11 15 18 22 29 29 29 29 |
2 2 3 5 5 6 7 9 11 13 15 15 15 15 15 |
*Indicates one hundred percent inspection. If sample size exceeds lot size, perform one hundred percent inspection. Accept the lot represented on zero nonconforming characteristics and reject the lot represented on one or more nonconforming characteristics for all inspection levels. |
4.2.4 Inspection characteristics. Critical characteristics are characteristics whose noncon- formance to specified requirements is likely to result in hazardous or unsafe conditions for indi- viduals using, maintaining, or depending upon the product or whose nonconformance to specified requirements is likely to prevent performance of the tactical function of a major end item. Major characteristics are characteristics whose nonconformance to specified requirements is likely to result in failure or to reduce materially the usability of the item for its intended pur- pose. Minor characteristics are characteristics whose nonconformance to specified require- ments is not likely to reduce materially the operation or usability of the item for its intended purpose.
4.2.5 Classification of characteristics. Quality conformance examinations and tests shall be as specified in the following classification of characteristics paragraphs. When specified herein, accept on 0 and reject on 1 attributes sampling inspection shall be performed on the designated characteristics using the stated levels in table VIII for selection of sample sizes.
24
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business