5.1.30.1.3 CNC removed parts. Parts that have been removed from the CNC system shall be preserved in accordance with section 5.1.1.30.
5.1.30.1.4 Identification (ID) of CNC units disconnected from machines. The CNC system model number, ID number, nomenclature, and manufacturer's name shall be recorded on a tag and taped to the inside of the control cabinet door. This data shall also be stenciled on the shipping cover or container to ensure correct identification and matching of the machine control unit upon reassembly.
5.1.30.2 Cable, cord, and wire assemblies. Exposed wires, sockets, connector plugs, terminals, and openings in switches and junction boxes shall be sealed with tape conforming to ASTM D 5486/D 5486M. Cable, cord, and wire assemblies shall be cleaned and coiled to a minimum safe diameter with no kinks or other deformations and placed in a container conforming to Level A packing requirements of MIL-STD-2073-1.
5.1.30.3 Electrical heating elements. Electrical heating elements removed from the basic unit shall be individually preserved in accordance with method 10 of MIL-STD-2073-1 and packed in a container conforming to Level A packing requirements of MIL-STD-2073-1.
5.1.30.4 Electrical motors. Electrical motors detached from machines shall be preserved in accordance with Level A requirements of MIL-E-16298.
5.1.30.5 Transformers. Transformers shall be preserved in accordance with sections
5.1.30.5.1 through 5.1.30.5.3.
5.1.30.5.1 Transformer, distribution and hermetically sealed type. Distribution and hermetically sealed type transformers shall be preserved in accordance with method 10 of MIL-STD-2073-1.
5.1.30.5.2 Transformer, molded and encapsulated type. Molded and encapsulated type transformers shall be preserved in accordance with method 30 of MIL-STD-2073-1.
5.1.30.5.3 Transformer, open construction type. Open construction type transformers shall be preserved in accordance with method 50 of MIL-STD-2073-1.
5.1.31 Drawers and door assemblies. Sliding surfaces of drawer guides shall be coated with preservative grease conforming to MIL-PRF-23827, MIL-PRF-10924, MIL-PRF-81322, or approved commercial grease. Internal surfaces of door hinges shall be coated with preservative oil conforming to viscosity grade SAE 30 of MIL-PRF-21260 or approved commercial oil. In addition to the mechanical locks and latches, doors and drawers shall be secured with metal strapping conforming to ASTM D 3953 and ASTM D 4675. Fiberboard pads conforming to ASTM D 4727/D 4727M shall be placed between the strapping doors and drawers to prevent the strapping from marring the painted surfaces.
5.1.32 Frames, tanks, paint spray booths, and conveyor systems. Equipment of this type shall be handled as a unit or disassembled only to the extent necessary for preservation and ease of transportability. Unpainted metal surfaces shall be coated with a preservative compound conforming to grade 2 and grade 4 of MIL-PRF-16173. Bearings and fittings shall be preserved with