STEP 4. Proceed now to remove, replace, or handle the ESDS item only on the mat surface. Keep all other tools or non-ESDS items off the mat.
STEP 5. ESDS items to be returned (for example, condition code F) for repair or otherwise removed from the static dissipating mat should be packaged to prevent any further deterioration (see paragraph 5.2). Place item in antistatic pouch D, made from material conforming to MIL-DTL-81997, type II. Fold over opening and place in shielding bag E, made from material conforming to MIL-PRF-81705, type I. Fold the opening, and place a rubber band over this shielding bag. Do not use adhesive tape. Item can now be handled as you would any other non-ESDS item.
NOTES:
1. Do not disassemble the field service kit until all procedures have been completed.
2. Ground cord and wrist strap cord are usually connected together on the kit's ground snap(s).
3. Follow manufacturers test method and frequency for evaluating the electrical and mechanical characteristics of wrist strap and ground cord.